|
 |
Ultraviolet Water
Purification & Disinfection
|
|
|
UV
disinfection systems are
an
effective and
economical means of water purification and water disinfection,
by eliminating harmful
bacteria and other microbes from drinking water
supplies, regardless of source. UV
light
is suitable for water supplied from
rain tanks, springs, bores and surface sources such as lakes and
streams. UV is commonly used for water disinfection, uv sterilisation
and water treatment on a wide range of
water sources by many local municipal governments, councils, food,
dair, aquaculture, pharmaceutical, wine and brewing
industries and by thousands of domestic and industrial consumers
to ensure their water
is safe to drink.
Infralight
Technology will design and
supply a system that is suitable for your budget and requirements.
|
|
|
Standard
& Custom
Solutions
|
|
|
|
Infralight
supplies a wide range of uv disinfection and uv water treatment
systems, both standard and custom designs available. This means any flow
requirement can be met. The design of the Infralight UV series
is
intended to provide many years of reliable operation at an economical
price. The treatment chambers are usually 304 stainless steel (316
is available) with the option of plastic (369/900/1000 models
only) for seawater applications. A range of options is available to
customise the system but the basic specificationis suitable for
domestic, farm and light commercial use.
The SF Series
UV water
disinfection systems are designed for continuous operation treating
cold water at any flow from 0/min up to the specified design rate. The
SF series use standard low pressure UV lamps with single ended
connections for ease of lamp change. The SF range is suitable for
potable water , food and beverage use. Product is UL certified.
|
 |
|
Sizing of the UV System
|
|
|
|
Microorganisms
must be exposed to the UV light for a certain amount
of time. This is called the dose or more correctly fluency, measured as
joules/m2: Ws/m2. The amount of UV light required is dependednt on the
type of organism, but most systems are based on flows to eliminate E.Choli. The pathogen must be exposed
for a period of time by the correct amount of light at the right
wavelength of 254nm.The relationship between light volume and time is
critical for effective reduction. The dose of uv light required to
effectively achieve a % reduction is a logarithmic
relationship.
The dose of uv required to achieve 90%
reduction is calleda Log1 reduction. Doubling the amount of uv,
Log2, will achieve a 99% reduction. Log3: 99.9, Log4: 99.99,
log5:99.999. Most systems are designed to achieve a log4 reduction of
99.99%. E.Choli requires approximately 6mWs/cm2. To achieve a 99.99%
reduction, multiply this value by 4 which is 24mWs/cm2. Most ultraviolet disinfection systems are
designed for a minimum 30mWs/cm2 dosage.
Microorganism Inactivation
Chart 
|
 |
|
Pre-Filtering
|
|
|
|
Pre-filtration
is usually required
to ensure that particulate matter does not shield
micro-organisms from
the UV light. 20 micron cartridge filtration is the
usual minimum. In
cases with fine turbidity in the water, or if cysts like Giardia
or
Cryptosporidium may
be present finer filtration may be necessary. In
this case one micron filtration is required, usually but not
necessarily for the whole supply, filtration for the drinking tap only
may be practical. In drinking water treatment in particular the dual
barrier approach to disinfection of using one micron filtration
and UV
is strongly recommended for the security this provides the user. For
water containing high levels of sediment or iron, pretreatment with a
backwashing filtration system is likely to be cost effective.
|
 |
|
UV
Disinfection Units
for Domestic, Light Industrial and Farm Applications-Datasheets
|
|
|
|
|

|
|
|
|
|
Download SF Series Brochure 
The Steriflo domestic UV water
disinfection systems are aneffective and economical means of
eliminating harmful bacteria and other microbes from drinking water
supplies, regardless of source.
|
|
|
HW
Series-Commercial
Hot Water UV Systems
Designed for ecomical
disinfection of hot water in a
wide variety of applications particularly large building hot water
systems. Flow rates up to 10000l/hr |
|
|
CS
Series- Commercial
UV Steriliser for Flows up to 15-20000l/hr
Designed
for economical use
but with a comprehensive
electrical system for industrial installation including electropolished
stainless steel AS316, calibrated uv meter, optional connection
fittings including BSP, RJT, Triclamp and Flange, IP65 rating for the
electrical enclosure, uv transmittance meter, hours counter, alarm
output, uv lamp failure alarm.
Ultraviolet Waste
Water Treatment Systems
Our range is wider and more flexible
thanthat offered by any other manufacturer.Three basic designs are
available. This means the end user gets the most appropriate
systempossible, designed to suit the wastewater plantand its operation,
maximising operatorconvenience and keeping operating costs aslow as
possible.For open channels the choice is betweenvertical lamps (CV
series) in modules ofthirty or thirty six, or horizontal racks withfour
to ten lamps per rack (CH series).These modules or racks can be
arranged tosuit the plant as required.
|
 |
|
Ultraviolet
& Infrared Products- Leaders in UV IR Technology
|
 |
|
|
|